Skip to content

Protocol

You only need this page to write a client in a new language. All you need is a WebSocket library and a JSON parser. Everything here is defined in the popsub_protocol crate, and docs/protocol/ has a JSON Schema for every frame.

Each frame is one JSON object in a WebSocket text message, with a type saying what it is:

{ "type": "publish", "id": 4, "topic": "orders/42", "payload": "order 42 shipped", "qos": 1 }

Put an id on any request, a number or a string, and the reply carries it back. Match replies by id, not by the order they arrive in: in the session below, a message overtakes the published reply to the same publish.

Frames the server sends on its own, like message, truncated and stalled, have no id.

Payloads are always strings. To send bytes, base64 them and add "encoding": "base64". The server stores the string as it is and never decodes it.

A connection sends login and gets a token, then sends auth and is authenticated, after which it subscribes, publishes and acknowledges, and sends auth again with a fresh token before the old one expires. The server closes it with 4002 for a request before auth, 4001 for a bad token, and once authenticated with 4004 when the token expires, 4005 after 90 seconds of silence, or 4003 when another connection takes over its session. subscribe, publish, ack, re-authloginlogged_inauthauthenticatedrequest before auth: 4002connectedbad token: 4001has a tokentoken expired: 4004idle 90 s: 4005taken over: 4003authenticatedclosed, with a code that says whether to reconnect

A connection logs in, then sends auth with the token. Anything other than login, register or ping before that is refused and the connection is closed. Once authenticated, it can do everything else. A minute before the token expires the server sends auth_expiring, and the client logs in again and sends a fresh auth on the same connection.

The server sends a WebSocket ping every 30 seconds and closes a connection it hasn’t heard from in 90. WebSocket libraries answer pings on their own. In a browser, where you can’t see them, send {"type":"ping"} now and then instead.

auth also carries the protocol version, currently 1. Within a version, frames, fields and error codes are only ever added. Ignore fields and frame types you don’t know, and treat an unknown error code like internal.

Recorded against a local server with a short Node script. → is the client, ← the server, and only the token is shortened.

→ {"type":"login","id":1,"username":"alice","password":"alice-password"}
← {"id":1,"type":"logged_in","token":"eyJ..."}
→ {"type":"auth","id":2,"token":"eyJ...","protocol":1,"session_id":"orders-worker","hold_resumed":true}
← {"id":2,"type":"authenticated","protocol":1,"session_id":"orders-worker","held":true,"limits":{"max_inflight":100,"session_expiry_secs":86400,"heartbeat_secs":30,"idle_timeout_secs":90,"max_payload_bytes":1048576,"max_topic_bytes":120}}
→ {"type":"subscribe","id":3,"topic":"orders/42","from":{"seq":1}}
← {"id":3,"type":"subscribed","topic":"orders/42","replay_from":1,"replay_to":0}
→ {"type":"publish","id":4,"topic":"orders/42","payload":"order 42 shipped","qos":1}
← {"type":"message","topic":"orders/42","seq":1,"message_id":"fcdeb6b4-5768-4f66-972b-fefa068a9154","payload":"order 42 shipped","qos":1,"published_at_ms":1795413947884}
← {"id":4,"type":"published","message_id":"fcdeb6b4-5768-4f66-972b-fefa068a9154","seq":1}
→ {"type":"ack","topic":"orders/42","seq":1}
→ {"type":"publish","id":6,"topic":"news/today","payload":"hello","qos":1}
← {"id":6,"type":"error","code":"not_authorized","message":"not authorized to publish to 'news/today'"}

replay_from 1 and replay_to 0 means there was no history to replay. The ack has no reply. The error carries the id of the request it answers, and the connection stays open.

Connecting again later with the same session_id, the server lists the session’s topics and resumes after the acknowledged message:

← {"id":2,"type":"authenticated","protocol":1,"session_id":"orders-worker","resumed":["orders/42"],"held":true,"limits":{...}}
→ {"type":"subscribe","id":3,"topic":"orders/42","from":"resume"}
← {"id":3,"type":"subscribed","topic":"orders/42","replay_from":2,"replay_to":1}
Request Fields Reply
login username, password logged_in with a token
register username, password registered, if the server allows it
auth token, protocol, session_id, clean_start, hold_resumed authenticated
subscribe topic, from, group subscribed, then history, then live messages
unsubscribe topic unsubscribed
publish topic, payload, qos, message_id, encoding published at QoS 1, nothing at QoS 0
ack topic, seq nothing
ping pong

Only topic, payload, token, username, password and seq are required. from takes "resume", "new", {"last": N}, {"since_ms": T} or {"seq": S}, as described in Topics and replay. hold_resumed is explained in Durable sessions.

Frame Fields When
message topic, seq, message_id, payload, qos, published_at_ms, encoding For every message delivered, replayed or live
subscribed topic, replay_from, replay_to, group After subscribe, and for each topic a pattern joins
truncated topic, first_available Messages you were due have been trimmed
stalled topic, seq A QoS 1 message ran out of retries
unsubscribed topic After unsubscribe, or when access was revoked
auth_expiring expires_at_ms A minute before the token expires
error code, message, retry_after A request failed. See Errors and close codes.

authenticated carries a limits object with the numbers a client needs: max_inflight, session_expiry_secs, heartbeat_secs, idle_timeout_secs, max_payload_bytes and max_topic_bytes.

An enabled admin can manage accounts and topics over the same connection. Anyone else gets forbidden. These are what popsub users and popsub topics send.

Request Fields
create_user username, password, role
get_user, delete_user username
list_users, list_topics
set_role username, role
grant username, pattern, access
revoke username, pattern
set_password username, password
set_enabled username, enabled
get_topic, purge_topic topic

A role looks like {"kind": "user", "topics": [{"pattern": "orders/#", "access": "both"}]}, where kind is admin, user or readonly and access is subscribe, publish or both.

docs/protocol/ is generated from the protocol types, and CI fails if it falls out of date. client.schema.json covers every frame a client sends, server.schema.json every frame the server sends, and close-codes.json the close codes and whether to reconnect after each. Generate your client’s types from them.

A library needs more than the frames to be reliable: reconnecting, resubscribing without gaps, dropping duplicates. clients/README.md lists all of it, and a shared scenario suite holds every library in the repository to it.